Connector — electrical
M12 D-coded connector
- Slug
- m12-d-coded
- Domain
- electrical
- About
- M12 D-coded connector: 2-pair, 100 Mbit ceiling. Replaces the coding-blind m12-connector for fast-Ethernet ports.
Plug
- Family
- M12
- Coding
- D
- Contacts
- 4
- Standard
- IEC 61076-2-101:2012
- Rating
- 250 V DC · 250 V AC · 4 A per contact
- Face
- schematic — contact positions not read from a figure
- Source
- IEC 61076-2-101:2012 §3.2.2 + Table 1: D-coding has 4 contacts, 250 V a.c./d.c., 4 A, tested to 100 MHz.
Products using this connector(13)
- socket×1
- socket×1
- socket×1
- socket×1
- socket×1
- socket×1
- socket×1
- socket×2
- socket×2
- plug×1
- plug×1
- SX5-M70
pairs with Datalogic SLS-M5-1708-E, Datalogic SLS-SA3-08 +5
plug×1 - socket×2