A · Robotiq 2F-140

M12 · 5-pin

male · plug

coupling pigtail (5-pole male end)

M12, 5 contacts, 5 with a recorded signalM121RS485 GND224 V3GND4RS485 +5RS485 -

Other plugs:M8 · 8-pin · cable-to-wrist coupling

B · Universal Robots UR5e

M8 · 8-pin

female · sockets

tool-side connector

M8, 8 contacts, 8 with a recorded signalM81AI3 / RS485-2AI2 / RS485+3TO0/PWR4TO1/GND5POWER6TI07TI18GND

Other plugs:M8 · 8-pin · tool-side connector

Swap sides · Pick another counterpart

The cable

End at A
M12 · 5-pin · female
End at B
M8 · 8-pin · male

Different plug families: an adapter cable, one end for each plug.

Wires (4)

Robotiq 2F-140Universal Robots UR5eRS485 GND (pin 1) — GND (pin 8)24 V (pin 2) — POWER (pin 5)◀RS485 + (pin 4) — AI2 / RS485+ (pin 2) · confirm A/B naming◆RS485 - (pin 5) — AI3 / RS485- (pin 1) · confirm A/B naming◆Pin 1: RS485 GND (ground)1RS485 GNDPin 2: 24 V (supply)224 VPin 3: GND (ground)3GNDPin 4: RS485 + (RS-485 A)4RS485 +Pin 5: RS485 - (RS-485 B)5RS485 -Pin 1: AI3 / RS485- (RS-485 B)1AI3 / RS485-Pin 2: AI2 / RS485+ (RS-485 A)2AI2 / RS485+Pin 3: TO0/PWR (digital out)3TO0/PWRPin 4: TO1/GND (digital out)4TO1/GNDPin 5: POWER (supply)5POWERPin 6: TI0 (digital in)6TI0Pin 7: TI1 (digital in)7TI1Pin 8: GND (ground)8GND

▶ ◀ which way power or data flows · ◆ both ways · dashed: confirm the naming · hollow ring: left for your application

Wires, A to B
A · Robotiq 2F-140B · Universal Robots UR5eFlow
1 RS485 GND · ground8 GND · groundcommon reference
2 24 V · supply5 POWER · supplyB → A
4 RS485 + · RS-485 A2 AI2 / RS485+ · RS-485 Aboth waysRS-485 A/B naming differs between vendors — confirm against both manuals
5 RS485 - · RS-485 B1 AI3 / RS485- · RS-485 Bboth waysRS-485 A/B naming differs between vendors — confirm against both manuals

Left for your application

General I/O is not wired here: which output drives which input is a choice in your program, not a property of the plugs.

Universal Robots UR5e

  • 3 TO0/PWR · digital out
  • 4 TO1/GND · digital out
  • 6 TI0 · digital in
  • 7 TI1 · digital in

No counterpart on the other plug

  • Robotiq 2F-140: 3 GND · ground

What each plug carries

Robotiq 2F-140
24 V DC supply on pin 2 · Modbus RTU (RS-485) on pins 4–5 · RS-485 serial on pins 4–5
Universal Robots UR5e
RS-485 serial on pins 1–2 · 24 V DC supply on pin 5

Check supply voltage and current against both data sheets before powering — the pinout says where the supply is, not how much.

Pins from Robotiq 2F-140 (source ↗) and Universal Robots UR5e (source ↗). Contact positions on the faces are schematic.