RSL 400
by Leuze electronic GmbH + Co. KG
Rotating-head safety scanner — up to 8.25 m and 270°, from classic I/O to PROFINET/PROFIsafe.
Compare models
11 of 19 specs differ across 3 models
| Spec | RSRSL410-XL | RSRSL420-M/CU411-RS4 | RSRSL450P-M/CU400P-AIDA-OF |
|---|---|---|---|
| General | |||
| Scanning Angle | 270 ° | 270 ° | 270 ° |
| Protective Field Range | 8.25 m | 4.5 m | 4.5 m |
| Response Time | 80 ms | 80 ms | 120 ms |
| IEC 61496 Type | Type 3 | Type 3 | Type 3 |
| Warning Field Range | 20 m | 20 m | 20 m |
| Angular Resolution | 0.1 ° | 0.1 ° | 0.1 ° |
| Number of Field Sets | 1 | 10 | 100 |
| SIL Rating | SIL 2 | SIL 2 | SIL 2 |
| Interface | M12 8-pin plug (CU408 connection unit, I/O + power); Ethernet TCP/IP and Bluetooth for configuration/diagnosis; 3 configurable signal outputs | Sub-D 15-pin machine I/O (450 mm PUR cable) + M12 4-pin D-coded Ethernet TCP/IP for configuration/diagnosis; Bluetooth/USB also supported on other RSL420 connection units; 2 PNP OSSD outputs | PROFINET/PROFIsafe (native, IRT-ready 2-port switch integrated in connection unit); Bluetooth + USB 2.0 for configuration/diagnosis |
| IP Rating | IP65 | IP65 | IP65 |
| PL Rating | PLd | PLd | PLd |
| Connector Type | M12 | D-sub | circular |
| Dimensions (L×W×H) | 140 × 149 × 140 mm (W×H×D, incl. connection unit) mm | 140 × 149 × 140 mm (W×H×L) mm | 140.2 × 200 × 142 mm (W×H×L) mm |
| No-load Average Current | 0.7 A | 0.7 A | 1 A |
| Operating Temperature Range | 0 ... +50 °C | 0 ... +50 °C (storage: -20 ... +60 °C) | 0 ... +50 °C (storage: -20 ... +60 °C) |
| Power Required | 17 W | 17 W | 24 W |
| Supply Voltage | 24 V DC, -30 ... +20 % | 24 V DC, -30 ... +20 % (16.8-28.8 V) | 24 V DC, -30 ... +20 % |
| Wavelength | 905 nm | 905 nm | 905 nm |
| Weight | 3 kg | 3 kg | 4.5 kg |