SX5
by Banner Engineering
Current-generation area scanner replacing the AG4 line — 275° coverage with Master/Remote expansion.
Compare models
2 of 16 specs differ across 4 models
| Spec | SXSX5-B6 | SXSX5-M10 | SXSX5-M70 | SXSX5-R |
|---|---|---|---|---|
| General | ||||
| Scanning Angle | 275 ° | 275 ° | 275 ° | 275 ° |
| Protective Field Range | 5.5 m | 5.5 m | 5.5 m | 5.5 m |
| Response Time | 482 ms | 62 ms | 62 ms | 62 ms |
| IEC 61496 Type | Type 3 | Type 3 | Type 3 | Type 3 |
| Warning Field Range | 40 m | 40 m | 40 m | 40 m |
| Angular Resolution | 0.1 ° | 0.1 ° | 0.1 ° | 0.1 ° |
| SIL Rating | SIL 2 | SIL 2 | SIL 2 | SIL 2 |
| Interface | M12 A-coded (8-pin) power + I/O + OSSD; M12 D-coded (4-pin) Ethernet TCP/IP for PC configuration/GUI. No fieldbus (no native EtherNet/IP/PROFIsafe). | M12 A-coded (8 or 12-pin) power + I/O + OSSD; M12 D-coded (4-pin) Ethernet TCP/IP for configuration/GUI; M12 A-coded (8-pin) Master-to-Remote link. No fieldbus (no native EtherNet/IP/PROFIsafe). | M12 A-coded (17-pin) power + I/O + OSSD; M12 D-coded (4-pin) Ethernet TCP/IP for configuration/GUI + up to 4-scanner safe comms bus (AGV multi-side monitoring); M12 A-coded (8-pin) Master-to-Remote link. No fieldbus (no native EtherNet/IP/PROFIsafe). | M12 A-coded (8-pin) Master-to-Remote link (safety outputs are on the paired Master); no independent I/O/OSSD connector. No fieldbus. |
| IP Rating | IP65 | IP65 | IP65 | IP65 |
| PL Rating | PLd | PLd | PLd | PLd |
| Communication Protocols | Ethernet TCP/IP (point-to-point configuration/GUI + up to 4 scanners on a safe Ethernet comms bus for AGV multi-side monitoring); not an EtherNet/IP fieldbus (no CIP Safety) | Ethernet TCP/IP (point-to-point configuration/GUI + up to 4 scanners on a safe Ethernet comms bus for AGV multi-side monitoring); not an EtherNet/IP fieldbus (no CIP Safety) | Ethernet TCP/IP (point-to-point configuration/GUI + up to 4 scanners on a safe Ethernet comms bus for AGV multi-side monitoring); not an EtherNet/IP fieldbus (no CIP Safety) | Ethernet TCP/IP (point-to-point configuration/GUI + up to 4 scanners on a safe Ethernet comms bus for AGV multi-side monitoring); not an EtherNet/IP fieldbus (no CIP Safety) |
| Dimensions (L×W×H) | 112.5 × 102 × 152 (D × W × H) mm | 112.5 × 102 × 152 (D × W × H) mm | 112.5 × 102 × 152 (D × W × H) mm | 112.5 × 102 × 152 (D × W × H) mm |
| Operating Temperature Range | -10 to +50 °C | -10 to +50 °C | -10 to +50 °C | -10 to +50 °C |
| Operating Voltage Range | 19.2–30 VDC | 19.2–30 VDC | 19.2–30 VDC | 19.2–30 VDC |
| Scan Rate | 33.3 Hz | 33.3 Hz | 33.3 Hz | 33.3 Hz |
| Weight | 1.5 kg | 1.5 kg | 1.5 kg | 1.5 kg |