SE2L
by IDEC Corporation
Compact 270°/5 m master-slave scanner — dual protection zones, links up to 4 units over RS-485.
Compare models
3 of 16 specs differ across 2 models
| Spec | SESE2L-H05LP | SESE2L-HA05LP |
|---|---|---|
| General | ||
| Scanning Angle | 270 ° | 270 ° |
| Protective Field Range | 5 m | 5 m |
| Response Time | 60 ms | 60 ms |
| IEC 61496 Type | Type 3 | Type 3 |
| Warning Field Range | 20 m | 30 m |
| Number of Field Sets | 32 | 128 |
| SIL Rating | SIL 2 | SIL 2 |
| Interface | USB 2.0 micro-B (PC config); RS-485 (Master/Slave, cable); Ethernet 100BASE-TX waterproof connector (distance-measurement data) | USB 2.0 micro-B (PC config); RS-485 (Master/Slave, cable); Ethernet 100BASE-TX waterproof connector (distance-measurement data) |
| IP Rating | IP65 | IP65 |
| PL Rating | PLd | PLd |
| Communication Protocols | USB 2.0 (PC config), RS-485 (Master/Slave link), Ethernet 100BASE-TX (distance-measurement data output) — no native EtherNet/IP or fieldbus safety protocol | USB 2.0 (PC config), RS-485 (Master/Slave link), Ethernet 100BASE-TX (distance-measurement data output) — no native EtherNet/IP or fieldbus safety protocol |
| Dimensions (L×W×H) | 80W × 80D × 95H mm mm | 80W × 80D × 95H mm (carried over from base model — unverified for Advanced) mm |
| Operating Temperature Range | -10 to +50 °C (no freezing) | -10 to +50 °C (no freezing) |
| Operating Voltage Range | 16.8–26.4 VDC | 16.8–26.4 VDC |
| Scan Rate | 33.3 Hz | 33.3 Hz |
| Weight | 0.8 kg | 0.8 kg |