Connector — electrical
M12 B-coded connector
- Slug
- m12-b-coded
- Domain
- electrical
- About
- M12 B-coded connector (IEC 61076-2-101): 5 contacts, keyed apart from A-coded M12. Pilz PSENopt II ships A- and B-coded variants that put +24 V on different pins.
- Reference
- https://cdn.standards.iteh.ai/samples/17784/aef8379d4a0e4eeb8223b2b41e611cf6/IEC-61076-2-101-2012.pdf
Plug
- Family
- M12
- Coding
- B
- Contacts
- 5
- Standard
- IEC 61076-2-101:2012
- Rating
- 60 V DC · 60 V AC · 4 A per contact
- Face
- schematic — contact positions not read from a figure
- Source
- IEC 61076-2-101:2012 §3.2.2 + Table 1: B-coding has 5 contacts, 60 V a.c./d.c., 4 A.
Products using this connector(1 of 1)
- plug×1