by Wieland Electric GmbH
Type 4 curtain platform with an SLG4 discrete-beam grid sharing the same housing.
4 of 14 specs differ across 4 models
| Spec | SLSLC4 Base 14mm | SLSLC4 Standard Muting 30mm | SLSLG4 Long Range | SLSLG4 Short Range |
|---|---|---|---|---|
| General | ||||
| Resolution | 14 mm | 30 mm | — | — |
| Protection Height | 900 mm | 900 mm | 1200 mm | 1200 mm |
| Response Time | 10 ms | 10 ms | — | — |
| Safety Category | Type 4 | Type 4 | Type 4 | Type 4 |
| Range | 10 m | 30 m | 70 m | 15 m |
| SIL Rating | SIL 3 | SIL 3 | SIL 3 | SIL 3 |
| Muting Capability | No | Yes | — | — |
| Interface | M12, 5-pole or 8-pole (depending on model), 23 cm pigtail | M12, 5-pole or 8-pole (depending on model), 23 cm pigtail | M12, 5-pole or 8-pole (depending on model), 23 cm pigtail | M12, 5-pole or 8-pole (depending on model), 23 cm pigtail |
| IP Rating | IP67 / IP65 | IP67 / IP65 | IP67 / IP65 | IP67 / IP65 |
| Operating Temperature Range | -30 to +55 degC (operating); -30 to +60 degC (storage) | -30 to +55 degC (operating); -30 to +60 degC (storage) | -30 to +55 degC (operating); -30 to +60 degC (storage) | -30 to +55 degC (operating); -30 to +60 degC (storage) |
| Output Current | 0.25 A | 0.25 A | 0.25 A | 0.25 A |
| PL Rating | PLe | PLe | PLe | PLe |
| Supply Voltage | 24 V DC +/-20% (nominal); operating range 0.8-1.2 x Un | 24 V DC +/-20% (nominal); operating range 0.8-1.2 x Un | 24 V DC +/-20% (nominal); operating range 0.8-1.2 x Un | 24 V DC +/-20% (nominal); operating range 0.8-1.2 x Un |
| Number of Beams | — | — | 4 | 4 |